HOME  /  SOLUTIONS  /  NETWORK MONITORING
SOLUTION

See what the network is doing, zone by zone

Most distribution networks are read once a month at the boundary. Between those readings, a burst, a closed valve or a meter drifting out of calibration is invisible. Continuous monitoring closes that gap.

An open district meter chamber
DISTRICT METER CHAMBER
01 — WHAT TO MEASURE

Flow, pressure and whatever else the site already measures.

District meters and zone boundaries, pumping stations, reservoir outlets, pressure-reducing valves and large consumer connections. Flow tells you how much is moving; pressure tells you how the network is behaving while it moves. Where a site carries other instrumentation, MODBUS RTU and 4–20 mA provision brings that into the same record rather than a second system.

Zone boundaries

The district meters that define where water enters and leaves.

Pumping stations

Where flow is created, and where a fault shows up first.

Reservoir outlets

What leaves storage, against what the zone below it receives.

PRVs and large consumers

Control points, and the connections big enough to move a balance.

02 — HOW IT’S SET UP

A typical configuration.

CHAMBER CX-LOG1.1 multi channel PULSEPRESSURE 4G District boundaryWhere the zone begins and the balance is struck.Every 15 minutesResolution enough to see a change, light on battery.
TYPICAL INSTALLATION — ONE MONITORING POINT
01Cx-Log1.1 on the existing meter’s pulse output, with the internal pressure transducer on the same asset.
02Sampling every 15 minutes, transmitting once or twice a day — enough resolution to see a change, light enough for years of battery.
03Minimum and maximum alarms on both channels, with SMS to the zone engineer.
04Site ID matched to your asset register, so the data lands where your team expects it.
03 — WHAT YOU SEE

In CLog.

A live list of every zone meter with its last reading and status, graphs of flow and pressure over any period, and exports for your monthly balance. Alarms surface the sites that moved out of range while you were looking elsewhere.

What it takes

One device per monitoring point, a SIM, and an hour on site to mount and configure it over Bluetooth.

What it doesn’t

No power, no cabling and no civil work in most chambers.

Where it goes next

Add reservoir outlets and large consumers as the scheme grows — same platform, one picture.

Instrument one zone and see.

Tell us the boundary meters and we will scope the devices, the sensors and the connectivity for a single district.