HOME  /  PRODUCTS  /  CX-LOG1.1
MULTI-CHANNEL DATA LOGGER

Cx-Log1.1

A rugged, configurable logger for water and gas distribution networks. Measures flow and pressure at the asset, holds 3.5 years of readings, and reports over 4G with 2G fallback — from a single meter point to a network-wide deployment.

IP68
INGRESS
4G / 2G
CELLULAR + FALLBACK
−20 / +85
°C OPERATING
5 years
TYPICAL BATTERY
Cx-Log1.1
01 — WHAT IT DOES

Measure, log, report, alarm.

Four jobs, each of them yours to configure. The settings trade against each other — faster sampling costs battery and data — so nothing is fixed in firmware you can’t reach.

Measure

Sampling from once a second to once every 24 hours. Faster sampling shortens battery life and raises data cost, so the rate is yours to set per channel.

Log

3.5 years of history on the primary channel, plus a secondary fast-logging channel for pulse counting, a MODBUS register or a 4–20 mA input.

Report

Transmit on a fixed interval, or in up to five programmable slots a day — set to balance data freshness against battery and data cost.

Alarm

Up to five threshold alarms on any logged value, minimum or maximum, with hysteresis and persistence. SMS to as many as eight numbers.

02 — INPUTS

Fits the metering you already have.

Four ways to feed it, on a primary and a secondary logging channel. If your meter has a pulse output, a MODBUS RTU interface or a 4–20 mA signal, the logger reads it — no meter replacement, no adaptor project.

CHANNEL INPUT
Digital pulse

Potential-free pulse input for flow counting, up to 100 pulses per second.

CHANNEL INPUT
Analogue pressure

0–20 bar gauge transducer, mV/V four-wire, accuracy class <0.25 % FS. 303 stainless housing, FKM seal, ¼″ NPT process connection. Other ranges on request.

CHANNEL INPUT
MODBUS RTU

Configurable serial input — slave ID, register, data type and format, baud rate, parity and timeout all set from CLog.

CHANNEL INPUT
4–20 mA

Available as the secondary fast-logging channel, for any transmitter that speaks the standard loop.

03 — COMMUNICATIONS

Four ways to reach the device.

Cellular

Internal 4G modem with automatic 2G fallback, so the device keeps reporting where coverage is thin. Readings are held on board and forwarded when the connection returns — an outage costs you nothing but latency.

Bluetooth

Local connection for setup, diagnostics and configuration changes, without opening a cellular session. Commissioning takes about an hour per chamber, and it is the only visit the device needs.

SMS on alarm

Up to eight programmable numbers, delivered as the breach happens. M2M SIM dialling is disabled for security, and some M2M SIMs do not support it at all.

Pass-by reading

An authorised engineer walking or driving past the chamber collects the device’s readings straight into the mobile app — no cellular session, no lid opened, no chamber entry. Useful where signal is poor or a site is read on a round.

04 — SPECIFICATION

Everything, on the page.

Published here rather than locked in a PDF you have to request. Configuration is set at order.

MEASUREMENT
Logging channelsPrimary + secondary fast-logging
Pulse inputPotential-free, ≤100 pulses/s
Pressure range0–20 bar gauge
Transducer outputmV/V, 4-wire
Accuracy class<0.25 % FS
Non-repeatability<0.1 %
SerialMODBUS RTU, configurable
Analogue4–20 mA, secondary channel
Sampling interval1 s to 24 h, per channel
On-device history3.5 years, primary channel
SENSOR
Housing material303 stainless steel
Seal materialFKM
Process connection¼″ NPT male
Electrical connectionM12×1, 4-pin
Supply2–30 V dc
COMMUNICATION
Cellular4G, automatic 2G fallback
SIMM2M; dialling disabled
LocalBluetooth configuration
TransmissionFixed interval, or ≤5 slots/day
Alarms≤5 thresholds, min/max
Alarm controlsHysteresis, persistence on/off
Alarm deliverySMS, ≤8 numbers
PHYSICAL & POWER
Ingress protectionIP68
EnclosureInsert-moulded ABS, gasket-sealed lid
FixingsCaptive M4 screws, blind brass inserts
Housing148 × 129 × 112 mm
Lid148 × 129 × 16 mm
MountingMetal clamp bracket
Operating range−20 to +85 °C
Battery lifeUp to 5 years, typical use
ENCLOSURE — OVERALL
129 mm 148 mm LID 16 DEEP HOUSING 112 DEEP
Housing depth 112 mm, lid 16 mm. Moulded ABS with blind brass inserts, gasket-sealed, captive screws retained in the lid so nothing drops into a wet chamber.
05 — APPROVALS

Certifications.

CE
GENERAL PRODUCT SAFETY
RoHS
SUBSTANCES

Certificates can be viewed online on the Resources page, or requested as a copy.

06 — WORKS WITH CLOG

Configured and read from one place.

Every Cx-Log reports to CLog, where you register the device, set its channels, alarms and MODBUS parameters, watch its readings and pull its history. Nothing about day-to-day operation needs a site visit.

CLog

Speak to an engineer about Cx-Log1.1.

Tell us the site and the meters, and we’ll tell you what it takes to monitor them — inputs, sensors, connectivity and the platform.

Send enquiry Download the datasheet